Sale!

CC-TAIX51  CC-TAIX01 CC-TAIX11  Analog Input IOTA Models

CC-TAIX51  CC-TAIX01 CC-TAIX11  Analog Input IOTA Models

The Series C Analog Input IOTA board is represented by the following information and graphic.
To access the parts information for the:
• module
• IOTA
• terminal plug-in assembly, and
• fuses
associated with this board and module, refer to Analog Input in the Recommended Spare Parts section.
Series C Analog Input 6 inch, non-redundant IOTA is displayed.
Categories: ,

Description

概观


Essential details:CC-TAIX51  CC-TAIX01 CC-TAIX11  Analog Input IOTA Models

The Series C Analog Input IOTA board is represented by the following information and graphic.
To access the parts information for the:
• module
• IOTA
• terminal plug-in assembly, and
• fuses
associated with this board and module, refer to Analog Input in the Recommended Spare Parts section.
Series C Analog Input 6 inch, non-redundant IOTA is displayed.

Individual field wiring is protected by an internal protection circuit permitting:
• Short circuit protection of input for field short circuits. Protection suitable for Division 2 non-incendive /
Zone 2 non-arcing.
• Each signal can be shorted in the field with no damage to module or board. Other channels on the same IOM
will not be affected

CC-TAIX51

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@saulcontrol.com

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

CC-TAIX51  CC-TAIX01 CC-TAIX11  Analog Input IOTA Models

The AI IOM/IOTA is optimized for use with classic two-wire transmitters. All 16 channels can accept inputs
from two-wire transmitters without any special wiring or jumper options.
The standard usage is to:
• reserve the first 12 channels of the AI IOM/IOTA for classic two-wire transmitters, and
• use the last 4 channels of the IOM/IOTA to interface any of the supported input styles (including two-wire
transmitters).
Depending on the input style applied to channels 13 through 16, you may need to cut jumpers on the IOTA and
apply wiring to the TB2 terminal block on the IOTA. This is discussed in detail in the following sections.

The IOTA is pre-engineered (without custom wiring) to accept sources that are not two-wire transmitters, but
you must use channels 13 through 16.
When sources other than two-wire transmitters are to be interfaced and you have more than 4 per IOTAs, then:
• the first four must be interfaced to channels 13 through 16, and
• the remainder may be able to interface to channels 1 through 12 (depending on input style) but you must
perform some degree of custom wiring.

Custom wiring means:
• using additional wires to TB2 (beyond their intended purpose for channels 13 through 16)
• and/or using wires to another termination area in the cabinet engineered on a project-basis.
Some of the styles (other than two-wire transmitter):
• can be applied to channels 1 through 12 with the use of custom wiring.
• Other cannot be applied to channels 1 through 12 at all.

04220FL11232A  Intelligent Platforms Rxi Controller PCIE-6321  DIO Multifunction I/O Device
LDGRB-01 3BSE013177R1  I/O Programmable Logic module PCIE-1427  779706-01  Frame Grabber
CI854AK01 3BSE030220R1  PROFIBUS-DP/V1 interface IC695CHS007  Universal backplane  RX3i and Series 90-30 I/O and option modules
TRICON  3511  TRICONEX  Pulse input module IC697CMM742-DC  Series 90-70 Communications Module
TRICON  3503E  TRICONEX  Digital input module FC-TSRO-0824  Digital Output Field Termination Assembly
TRICON  3625  TRICONEX  Digital input module MVC3001-4003A  ALSPA MV3000 Delta Controller
D674A906U01  Cartridge U-high HART 6SM57M-3.000  Synchronous Servomotors
VT-HNC100-1-23/W-08-0-0 R900955334  VT-HNC100 Digital Axis Controllers 05701-A-0282  Modbus Interface Module Kit RS422/485
1X00416H01  POWER SUPPLY  24V 300W & 25V 500W OUT DIN-RAIL MOUNT 3500/91 190782-01  EGD gateway module
5X00241G02  Ovation Westinghouse  Controller module 05701-A-0361  System 57 MODBUS Interface
489-P5-LO-A20  generator management relay 3500/65 145988-02  16-Channel Temperature Monitor
TRICON  3805E  TRICONEX  Analog Output Modules 3500/65  172103-01 16-Channel Temperature Monitor
5X00226G02  Ovation Westinghouse  Controller module 136188-02 Ethernet/RS485 Modbus I/O Module
MC-4/11/10/400  PowerDrive Motion Controller PCI-6733  Analog Output Device
2MLR-CPUH/T   MasterLogic  Programmable Logic Controller 3ASC25H209  DATX110   I/O board control module
KJ4002X1-BA1  Left 8 Wide Vertical Carrier CE4002S1T2B5  Standard I/O Termination Block
S72402-NANANA  S700  digital servo drive CE4005S2B4  Standard I/O Termination Block
SCYC55830 58063282A  Trigger plate PCI-4462  Sound and Vibration Device
IC697CMM742-DC  Ethernet Interface  Communications Modules TU890 3BSC690075R1  compact MTU for the S800 I/O
PPC322BE1 HIEE300900R1  Industrial drive function module KJ4001X1-BE1 12P0818X072 REV:L  8 Wide I/O Carrier with Shield Bar
VMIVME-3122  High-Performance 16-Bit Analog-to-Digital Converter (ADC) KJ2201X1-JA1  Redundant SLS Terminal Block
TVME200-10  6U VMEbus Carrier for up to 4 singlesize or 2 double-size IndustryPack (IP) modules AI895 3BSC690089R1  Analog Input Module
VMIVME-2540   Intelligent Counter/Controller AO2000 LS25  Advance Optima process analyzer’s modular