Description
概观
Essential details:CC-PAIN01 Analog Input Module
- Manufacturer : Honeywell
- Product Number : CC-PAIN01
- Product Type : Analog Input Module
- Input Type : Current (2-wire or self-powered transmitters)
- Notable Features : Extensive self-diagnostics, optional redundancy, supplies non-incendive field power and fast loop scan
- Weight : 0.35 kg
- Shipping Weight: 2 kg
The Series C Analog Input IOTA board is represented by the following information and graphic.
To access the parts information for the:
• module
• IOTA
• terminal plug-in assembly, and
• fuses
associated with this board and module, refer to Analog Input in the Recommended Spare Parts section.
Series C Analog Input 6 inch, non-redundant IOTA is displayed.
Individual field wiring is protected by an internal protection circuit permitting:
• Short circuit protection of input for field short circuits. Protection suitable for Division 2 non-incendive /
Zone 2 non-arcing.
• Each signal can be shorted in the field with no damage to module or board. Other channels on the same IOM
will not be affected
lf you need to inquire or purchase ,please send the product models to my email or call medirectly .
sunny He
[Email] sales@saulcontrol.com
[Mobile]Â 86-18059884797
[WhatsApp] 86-18059884797
[Skype] sales@saulcontrol.com
CC-PAIN01 Analog Input Module
The AI IOM/IOTA is optimized for use with classic two-wire transmitters. All 16 channels can accept inputs
from two-wire transmitters without any special wiring or jumper options.
The standard usage is to:
• reserve the first 12 channels of the AI IOM/IOTA for classic two-wire transmitters, and
• use the last 4 channels of the IOM/IOTA to interface any of the supported input styles (including two-wire
transmitters).
Depending on the input style applied to channels 13 through 16, you may need to cut jumpers on the IOTA and
apply wiring to the TB2 terminal block on the IOTA. This is discussed in detail in the following sections.
The IOTA is pre-engineered (without custom wiring) to accept sources that are not two-wire transmitters, but
you must use channels 13 through 16.
When sources other than two-wire transmitters are to be interfaced and you have more than 4 per IOTAs, then:
• the first four must be interfaced to channels 13 through 16, and
• the remainder may be able to interface to channels 1 through 12 (depending on input style) but you must
perform some degree of custom wiring.
Custom wiring means:
• using additional wires to TB2 (beyond their intended purpose for channels 13 through 16)
• and/or using wires to another termination area in the cabinet engineered on a project-basis.
Some of the styles (other than two-wire transmitter):
• can be applied to channels 1 through 12 with the use of custom wiring.
• Other cannot be applied to channels 1 through 12 at all.
04220FL11232AÂ Intelligent Platforms Rxi Controller | PCIE-6321Â DIO Multifunction I/O Device |
LDGRB-01 3BSE013177R1Â I/O Programmable Logic module | PCIE-1427Â 779706-01Â Frame Grabber |
CI854AK01 3BSE030220R1 PROFIBUS-DP/V1 interface | IC695CHS007 Universal backplane RX3i and Series 90-30 I/O and option modules |
TRICONÂ 3511Â TRICONEXÂ Pulse input module | IC697CMM742-DCÂ Series 90-70 Communications Module |
TRICONÂ 3503EÂ TRICONEXÂ Digital input module | FC-TSRO-0824Â Digital Output Field Termination Assembly |
TRICONÂ 3625Â TRICONEXÂ Digital input module | MVC3001-4003AÂ ALSPA MV3000 Delta Controller |
D674A906U01Â Cartridge U-high HART | 6SM57M-3.000Â Synchronous Servomotors |
VT-HNC100-1-23/W-08-0-0 R900955334Â VT-HNC100 Digital Axis Controllers | 05701-A-0282Â Modbus Interface Module Kit RS422/485 |
1X00416H01Â POWER SUPPLYÂ 24V 300W & 25V 500W OUT DIN-RAIL MOUNT | 3500/91 190782-01Â EGD gateway module |
5X00241G02 Ovation Westinghouse Controller module | 05701-A-0361 System 57 MODBUS Interface |
489-P5-LO-A20Â generator management relay | 3500/65 145988-02Â 16-Channel Temperature Monitor |
TRICONÂ 3805EÂ TRICONEXÂ Analog Output Modules | 3500/65Â 172103-01 16-Channel Temperature Monitor |
5X00226G02 Ovation Westinghouse Controller module | 136188-02 Ethernet/RS485 Modbus I/O Module |
MC-4/11/10/400Â PowerDrive Motion Controller | PCI-6733Â Analog Output Device |
2MLR-CPUH/T  MasterLogic Programmable Logic Controller | 3ASC25H209 DATX110  I/O board control module |
KJ4002X1-BA1Â Left 8 Wide Vertical Carrier | CE4002S1T2B5Â Standard I/O Termination Block |
S72402-NANANAÂ S700Â digital servo drive | CE4005S2B4Â Standard I/O Termination Block |
SCYC55830 58063282AÂ Trigger plate | PCI-4462Â Sound and Vibration Device |
IC697CMM742-DC Ethernet Interface Communications Modules | TU890 3BSC690075R1 compact MTU for the S800 I/O |
PPC322BE1 HIEE300900R1Â Industrial drive function module | KJ4001X1-BE1 12P0818X072 REV:LÂ 8 Wide I/O Carrier with Shield Bar |
VMIVME-3122Â High-Performance 16-Bit Analog-to-Digital Converter (ADC) | KJ2201X1-JA1Â Redundant SLS Terminal Block |
TVME200-10Â 6U VMEbus Carrier for up to 4 singlesize or 2 double-size IndustryPack (IP) modules | AI895 3BSC690089R1Â Analog Input Module |
VMIVME-2540Â Â Intelligent Counter/Controller | AO2000 LS25Â Advance Optima process analyzer’s modular |