Sale!

TC-ODK161 Honeywell Experion PKS system module

TC-ODK161 Honeywell Experion PKS system module

Manufacturers :Honeywell
Model(s)  :TC-ODK161
Additional Information :Experion PKS system module
Estimated Shipping Size
Dimensions: 263 × 58 × 28mm
Weight:.4.3 kg
Country of Origin: United States of America

 

Categories: , SKU: TC-ODK161

Description

Overview


Essential details:TC-ODK161 Honeywell Experion PKS system module

  • Manufacturer : Honeywell
  • Product No. : TC-ODK161
  • Product type : Experion PKS system module
  • Weight : 0.544 Kg
  • Shipping weight : 2 Kg

    TC-ODK161

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@xiongbagk.cn

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

TC-ODK161 Honeywell Experion PKS system module

A number of workplace applications are available to the DS200GDPAG1AKF. Integrated features include a 50 VAC output transformer, a control power supply, and a 120 VDC power supply. Both protective and control level circutries are found on this particular card. A number of onboard features allow for inputs to be safely and accurately captured and sent out. These include the 27 kHz inverter and the regulator as well as an input filter and an input rectifier. Each input found on this board is isolated, ensuring that some signals will not interfere with others on the board. Board status information is visually represented to users with the two neon and four LED indicators found on board.

System operation is reliant on users following all provided installation parameters. This will lessen the risk of any user injuries or drive accidents. Proper wiring is paramount in ensure drive safety. A complete instruction manual for wiring and installing DS200GDPAG1AKF is available in the series manual as well as the device datasheet. The board’s manufacturer, General Electric, originally provided technical support.

Frequently Asked Questions about DS200GDPAG1AKF

Where is the control power supply located on DS200GDPAG1AKF?
The control power supply for DS200GDPAG1AKF is located in between DS200GDPAG1AKF’s connections to the expander board and the cable assembly backplane on DS200GDPAG1AKF. These are all located on the far right bottom of the DS200GDPAG1AKF board. For a visual of where the control power supply on DS200GDPAG1AKF is located, view figure 1 in the manual for DS200GDPAG1AKF – Manual GEI-100287. Figure 1 in the manual is a GDPA Board Block Diagram.
How is DC input routed on DS200GDPAG1AKF?
For DS200GDPAG1AKF, DC input is routed from connector DCPL directly to the unregulated DC bus. If a DC source is not used on DS200GDPAG1AKF, optional ride-through capacitence may be connected. DC input for DS200GDPAG1AKF has a range of 105-140 VDC. The voltage range on the unregulated bus connected to DS200GDPAG1AKF is 94-178 VDC.
What happens when an overcurrent signal appears in the inverter?
Because of DS200GDPAG1AKF’s protective circuits functions, when an overcurrent signal appears on DS200GDPAG1AKF’s inverter, indicating the output of DS200GDPAG1AKF is shorted or overloaded, DS200GDPAG1AKF limits output current by reducing the P80 output rather than tripping the inverter. The overcurrent reference level on DS200GDPAG1AKF is reduced as the voltage on P80 is reduced. Inverter overcurrent and P80 overvoltage are two protective functions the DS200GDPAG1AKF board’s protective circuits have.
How do I find the manual for DS200GDPAG1AKF?
We can send you the manual for DS200GDPAG1AKF. We can send you the manual via manual link or manual hard copy. The manual for DS200GDPAG1AKF is Manual GEI-100287 and this manual is the GE Industrial Systems High Frequency Power Board Manual, a specific manual to DS200GDPAG1AKF.