Sale!

MVI46-MCM Modbus Master/Slave Communication Module

The MVI46 Modbus Master/Slave Communication Module allows Rockwell Automation SLC processors to interface easily with other Modbus protocol compatible devices.
Compatible devices include not only Modicon PLCs (which all support the Modbus protocol) but also a wide assortment of end devices. The module acts as an input/output module between the Modbus network and the Rockwell Automation backplane. The data transfer from the processor is asynchronous from the actions on the Modbus network.
Features and Benefits
The inRAx Modbus Master/Slave Communications module is designed to allow SLC processors to interfaceeasily with Modbus protocol-compatible devices and  hosts.
The MVI46-MCM module acts as an input/output module between the Modbus network and the Rockwell

Categories: ,

Description

Overview


Essential details:MVI46-MCM Modbus Master/Slave Communication Module

The MVI46 Modbus Master/Slave Communication Module allows Rockwell Automation SLC processors to interface easily with other Modbus protocol compatible devices.
Compatible devices include not only Modicon PLCs (which all support the Modbus protocol) but also a wide assortment of end devices. The module acts as an input/output module between the Modbus network and the Rockwell Automation backplane. The data transfer from the processor is asynchronous from the actions on the Modbus network.
Features and Benefits
The inRAx Modbus Master/Slave Communications module is designed to allow SLC processors to interfaceeasily with Modbus protocol-compatible devices and  hosts.
The MVI46-MCM module acts as an input/output module between the Modbus network and the Rockwell
Automation backplane. The data transfer from the SLC processor is asynchronous from the actions on the Modbus network. A 5000-word register space in the module exchanges data between the processor and the Modbus network.
Many host SCADA packages support the Modbus protocol, while devices commonly supporting the protocol include several PLCs, as well as many other third party devices in the marketplace. (For a partial list of devices that speak Modbus, please visit the ProSoft Tested section of the ProSoft Technology web site).

MVI46-MCM 

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@xiongbagk.cn

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

MVI46-MCM Modbus Master/Slave Communication Module

General Specifications
• Single Slot – 1746 backplane compatible (Local or extended I/O rack only. Remote rack not supported)
• The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module using M0/M1 files
• Ladder Logic is used for data transfer between module and processor
• Configuration data obtained through user-defined ladder. Sample ladder file included

Functional Specifications
Some of the general specifications include:
• Support for the storage and transfer of up to 5000 registers to/from the SLC processor’s data files
• Module memory usage that is completely user definable
• Two ports to emulate any combination of Modbus master or slave device
• Supports Enron version of Modbus protocol for floating point data transactions.
Slave Specifications
The MVI46-MCM module accepts Modbus function code commands of 1, 2, 3, 4, 5, 6, 8, 15, 16, 17, 22 and 23 from an attached Modbus master unit. A port configured as a Modbus slave permits a remote master to interact with all data contained in the module. This data can be derived from other Modbus slave devices on the network, through a master port, or from the SLC processor.