LDP1WC-62  LOW PRESSURE MONITOR 

Operation
High and low limit alarms are independently set from the front panel. In normal operation, the LED display will indicate the sensed pressure and the High Limit/Low Limit LED status indicators will be green. When a preset limit is exceeded, the LED signals an alarm condition by turning red. After a customer selected time delay, the electromechanical relay contacts will be latched open and the LED display will flash the process pressure once every second. Manually depressing the reset button will cause the relay contacts to close if and when the process pressure is within set limits.

Categories: ,

Description

Overview


Essential details:LDP1WC-62  LOW PRESSURE MONITOR 

Operation
High and low limit alarms are independently set from the front panel. In normal operation, the LED display will indicate the sensed pressure and the High Limit/Low Limit LED status indicators will be green. When a preset limit is exceeded, the LED signals an alarm condition by turning red. After a customer selected time delay, the electromechanical relay contacts will be latched open and the LED display will flash the process pressure once every second. Manually depressing the reset button will cause the relay contacts to close if and when the process pressure is within set limits.
Maintenance Mode
The “Maintenance Mode” option is a unique and convenient safety feature which allows the user to widen the alarm set points during system maintenance. By closing terminal circuits 3 and 4, using a key switch or password protected computer, the user can expand the limits to 5% and 95% of the range to continue monitoring and prevent false trips. Opening terminal circuits 3 and 4 immediately returns the set points to the previous settings.
Time Delay
ECHOLINE® includes an adjustable “stand alone” time delay to prevent intermittent tripping due to brief transient upsets. When the unit senses a pressure outside the limits, the status LED will immediately turn red, but the relay will not open for a pre-selected time delay. The time delay will reset to zero if the process pressure returns to within the limits during the transient conditions. This feature provides a degree of “fault tolerance” for exhaust flow interlock applications. The time delay is field settable through a jumper located on the rear of the enclosure for 1, 10, 20 or 30 seconds.
ECHO Diagnostics
The ECHO function is an internal electronic check of certain circuit parameters. In the event of an internal failure, the ECHO output relay immediately opens to communicate the fault condition and the unit display goes blank. The electromechanical output relay has isolated contacts that monitor the circuit in real time.

LDP1WC-47

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@xiongbagk.cn

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

LDP1WC-62  LOW PRESSURE MONITOR

ECHOLINE® was created using widely accepted best practices in an AS 9100 / ISO 9001 quality environment. Components used in the design and production of ECHOLINE® have been selected for their time proven performance, availability and reliability. ECHOLINE® contains no moving parts that can wear out, or microprocessors that are susceptible to hidden software problems.
When Used To Provide Safety Interlock, Monitor Ventilation Or Optimize Exhaust, ECHOLINE®
Features:
• Discrete all analog electronic components – no microprocessor
• Self-monitoring “ECHO” diagnostics
• Complies with the requirements of UL 991 and UL 508
• Fault tolerant design
• Maintenance mode
• User selected time delay
• Convenient interfacing with facility alarm system
When Used To Monitor Non- Critical Ventilation, ECHOLINE®
Features:
• Maintenance mode to prevent false trips during ventilation system balancing
• Optional non-latching relay
• Bright LED display of process pressure