FWA-EC0DR3-SGP-01VRS-MS Analog- and Parallelinterface

For the example in the graphic, “F2” and “28” are shown alternately on the H1-Display.

The control system can read out the diagnostic number in hexadecimal form with the S-0-0390, Diagnostic message number parameter.

In addition, the drive allocates to the control system the diagnostic number and diagnostic text as a string F228 Excessive deviation with the S-0-0095, Diagnostic message parameter.

The diagnostic number appears on this two-positional seven-segment display. The image can be seen on the “Diagnostic Message Priority Display”.

Categories: ,

Description

Overview


Essential details:FWA-EC0DR3-SGP-01VRS-MS Analog- and Parallelinterface

For the example in the graphic, “F2” and “28” are shown alternately on the H1-Display.

The control system can read out the diagnostic number in hexadecimal form with the S-0-0390, Diagnostic message number parameter.

In addition, the drive allocates to the control system the diagnostic number and diagnostic text as a string F228 Excessive deviation with the S-0-0095, Diagnostic message parameter.

The diagnostic number appears on this two-positional seven-segment display. The image can be seen on the “Diagnostic Message Priority Display”.

This display quickly shows the current operation status without the use of a communications interface.

The operating mode cannot be seen from the H1-Display. If the drive follows the operating mode and no command was activated, then the symbol “AF” appears on the display.

If more than one diagnostic message is waiting, then the message with the highest priority will be displayed.

The following graphic classifies operation status in order of importance.

DKC11.1-040-7-FW

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@xiongbagk.cn

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

FWA-EC0DR3-SGP-01VRS-MS Analog- and Parallelinterface

The clear coded diagnostic message contains the diagnostic number followed by the diagnostic text, as shown in the example, “Excessive Output Error” (Fig. 1-1). It can be read out with the S-0-0095, Diagnostic  message parameter and directly displays the operation status on an operator surface.

The clear coded diagnostic message will be switched to the current language.

  • Rexroth Indramat GmbH is not liable for damages resulting from failure to observe the warnings given in these documentation.
  • Order operating, maintenance and safety instructions in your language before starting up the machine. If you find that due to a translation error you can not completely understand the documentation for your product, please ask your supplier to clarify.
  • Proper and correct transport, storage, assembly and installation as well as care in operation and maintenance are prerequisites for optimal and safe operation of this equipment.
  • Trained and qualified personnel in electrical equipment :

Only trained and qualified personnel may work on this equipment or within its proximity. Personnel are qualified if they have sufficient knowledge of the assembly, installation and operation of the product as well as an understanding of all warnings and precautionary measures noted in these instructions. Furthermore, they should be trained, instructed and qualified to switch electrical circuits and equipment on and off, to ground them and to mark them according to the requirements of safe work practices and common sense. They must have adequate safety equipment and be trained in first aid.

  • Only use spare parts and accessories approved by the manufacturer.
  • Follow all safety regulations and requirements for the specific application as practiced in the country of use.
  • The equipment is designed for installation on commercial machinery. European countries: see directive 89/392/EEC (machine guideline).
  • The ambient conditions given in the product documentation must be observed.
  • Use only safety features that are clearly and explicitly approved in the Project Planning manual.

For example, the following areas of use are not allowed: Construction cranes, Elevators used for people or freight, Devices and vehicles to transport people, Medical applications, Refinery plants, the transport of hazardous goods, Radioactive or nuclear applications, Applications sensitive to high frequency, mining, food processing, Control of protection equipment (also in a machine).

  • Start-up is only permitted once it is sure that the machine, in which the product is installed, complies with the requirements of national safety regulations and safety specifications of the application.
  • Operation is only permitted if the national EMC regulations for the application are met.

The instructions for installation in accordance with EMC requirements can be found in the INDRAMAT document “EMC in Drive and Control Systems”.

The machine builder is responsible for compliance with the limiting values as prescribed in the national regulations and specific EMC regulations for the application.