EK52 6ZA963-7  Universal Operator Panels

3 V 270mA Lithium, not rechargeable,life about l year, user replaceable,model: CR2430.Change with same battery orequivalent with the work temperature ofUniOP(for eTOP04C 3V 50mAh Lithium, rechargeable,not user-replaceable, model VL2330)2 A T user replaceable(except the models CP10G-04,ePAD03/04/05/06MKDG-06,ePAD33C andeTOP03/04/05/06/20/33/40/50 that are equippedwith an overcurrent protection device)
Categories: ,

Description

Overview


Essential details:EK52 6ZA963-7  Universal Operator Panels

DC 18 -30 V
3 V 270mA Lithium, not rechargeable,life about l year, user replaceable,model: CR2430.Change with same battery orequivalent with the work temperature ofUniOP(for eTOP04C 3V 50mAh Lithium, rechargeable,not user-replaceable, model VL2330)2 A T user replaceable(except the models CP10G-04,ePAD03/04/05/06MKDG-06,ePAD33C andeTOP03/04/05/06/20/33/40/50 that are equippedwith an overcurrent protection device)

The unit must always be grounded to earth. Grounding helps limit the effects of noisedue to electromagnetic interference on the control system.Earth connection will have to be done using either either the screw or the fastonterminal located near the power supply terminal block. A yellow label help identifythe ground connection. Also connect to ground the terminal 3 on the power supplyterminal block.
The power supply circuit may be floating or grounded. In the latter case connect toground the power source common as shown in figure 42 with a dashed line.When using the floating power scheme, note that the panels internally connect thepower commond to ground with a l M resistor in parallel with a 4,7 nF capacitor.The power supply must have double or reinforced insulationThe suggested wiring for the power supply is shown in figure 36.

EK52 6ZA963-7

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@xiongbagk.cn

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

EK52 6ZA963-7  Universal Operator Panels

All the electronic devices in the control system must be properly grounded.
Grounding must be performed according to applicable regulations.
PLC Port
The PLC Port is used to communicate with the PLC or with another type ofcontroller, if the panel is configured as an UniNET client, then this port may be usedfor the network conneetion.Different electrical standards are available for the signals in the PLC port connector.RS-232,RS-422,RS-485 or Current Loop 20 mA. The cable used selects theappropriate signals. It is always necessary to use the correct cable type for on the PLCto be connected.
The function of the PC/Printer Port depends on the mode of operation ofthe panelConfiguration Modeprogramming portconnection to UniNETconnection to serial printer
Operation Mode, UniNET ServerOperation Mode, UniNET not active or Client node
Only RS232 signals are available on the PC/Printer Port. The connector is a D-l5 pinfemale. Pin assignment is shown in the table below.
The procedure to mount the communication modules is the followingl) turn off the unit2)partially unscrew with a screwdriver the 2 screws holding the rear cover. Thescrews are labelled ‘A’in Figure 443)remove the cover (for eTOP05/05EB/06/06C/20C/33C/40C/50C and ePAD33Clever with screwdriver on the slot on the cover’s side).4) plug the module in the red connectors, make sure the connectors are locked5)replace the rear coverfix the 2 screws ‘A’(for eTOP05/05EB/06/06C/20C/33C/40C/50C and ePAD33C6)close the cover with a little pressure).stick in the area ‘B’ the label describing the functionality of the AUX Port. The7label is delivered with the modules