Essential details:CI861K01 3BSE058590R1 VIP Communication Interface ABB
CI861/3BSE058590R1 Shielded cable shall use twisted pair core as far as possible for:
•RS 485 Multi-point tool communication CI861/3BSE058590R1
• Tachometer/pulse transmitter
•PTC sensor
• If other analog signals are used, such as weighing sensor sensors
The routing and grounding of RS 485 multiplexes are described on the previous page. For other connections
To shield signal cables, we need to consider the following rules:
1) A maximum of 20 mm of wire can be seen outside the end of the screen
2) The screen should be grounded directly through the spring pressure clamp, or use a tail grounding less than 20mm in length. if
Through the capacitor ground, the length of the capacitor leg should be as short as possible.
3) At only one point, the grounding of each shielded network should be directly grounded.
4) All other ground points shall be grounded through 0022 microF/250 V AC (1000 V DC)
A capacitor. Property: Application: Y-type filter capacitor, i.e. installed in
Live and grounded; Design: Metal paper (self-healing); Capacitance: 0022 microF; Voltage: 250 V
Ac (1000 volts DC). Example: Evox Rifa, PME 271 0022 microF.
5) Direct grounding of the screen is carried out in the control system module DARA 1000/1001/1010.
Do not install any terminal boards in the cabinet/panel. Shielded cables should be connected directly to the DARA 1000/1001/1010 and its accompanying spring pressure clamp. Example: Pulse
Encoder for crane on trolley. Example: PTC for crane travel motor.
6) For shielded cables from DARA to the transducer that do not pass through any junction box, please
Shielded cable shielded isolation mark at transducer end. This cable must be fixed directly to
CI861/3BSE058590R1 should be constructed using a crane or conduit instead of laying on cable ladder racks. For example: PTC for crane driving motor.
7) For cables routed through junction boxes, factory suitable shielded cables need to be used several times
Floral part of the responsibility. The next page describes how to design a junction box.
8) For the shielded cable from the junction box of the trolley to the sensor, leave a cable shielding isolation remark
At the end of the transducer. The cable must be fixed directly to the steel structure of the crane or conduit
Should be used instead of, for example, laying on cable ladder racks.
9) Separate the unshielded end of the shielded cable from other control voltages and supply voltages.
10) If possible, bring signals from the same transducer close to each other in the cable.
lf you need to inquire or purchase ,please send the product models to my email or call medirectly .
Sales Manager: Manager He
E-mail number: sales@saulcontrol.com
skype/ wechat: +86-18059884797
Mobile phone/wechat: +86-18059884797
QQ:3095989363
Same day shipment of 1000 parts
My company under the Sales and Marketing Department, technical engineering Department, after-sales service department, the department of comprehensive management. We can help your business with good service.
1. Sales Department 24/7 service. Handles your requests for any PLC DCS products in a timely manner with patience and professionalism.
2. The engineering department ensures that the products have no quality problems. All products will be inspected before shipping.
3. The financial department checks the payment and refund in time.
4. The warehouse department will carefully check the list of goods, carefully pack them, and deliver the goods in time.
5. After-sales Service Department has a full-time after-sales service team, subordinate to the sales department, and users can timely respond to service requests.
Superiority products CI861K01 3BSE058590R1 VIP Communication Interface ABB
ABB LXN1604-6 | HIMA HIMA 4135A | BENTLY 3500/22M 138607-01 |
TEWS TPMC815-11 | Reliance 61C350 | BENTLY 3500/22M 288055-01 |
TRICONEX 4351B | SAMS0N 45-4 | BENTLY 2300/25-00 |
ENTERASYS A4H254-8F8T | EMERSON 38B5786X092 | KEBA CP450/C |
BENTLY 3500/15 106M1079-01 | ENTERASYS A4H124-24TX P0973JM | ABB PM803F 3BDH000530R1 |
ABB UNITROL 1020 UNS0119A-Z,V1 3BHE030579R0003 | SCHUMACHER ATCS-15 1464-0320 | PROSOFT MVI56-PDPMV1 |
B&R 5AP920.1505-01 | FOXBORO FBM230 P0926GU | Eaton MTL831C |
ABB UNITROL 1020 | GE F650-N-F-L-F-2-G-1-HI-P-6E | BENTLY 3500/22M |
GE IS215UCVEM09B | Sartorius MDB-8E | BENTLY 3500/33 |
EPRO PR9268/601-000 | EMERSON 1C31203G01 | Fireye 48PT2-1007 |
ABB V17152-310 | A-B 1756-RM/A | SECURITY COMPANY BLL510 |
ABB AO2000-LS25 | A-B 1756-L63/B | GE IC754VGF12CTD |
DANAHER S20660-SRS | A-B 1756-CN2R/B | ADEPT 10350-00104 |
HIMA F7126 | A-B 1756-EN2T/B | ABB PHARPS32000000 |
HIMA F7131 | A-B 1756-PA72/C | HONEYWELL CC-TDIL61 |