Sale!

3500/33-01-00 16-Channel Relay Module BENTLY NEVADA

3500/33-01-00 16-Channel Relay Module BENTLY NEVADA

Manufacturers :BENTLY NEVADA
Model(s)  :3500/33-01-00
Additional Information :16-Channel Relay Module
Estimated Shipping Size
Dimensions: 263 × 58 × 28mm
Weight:.4.3 kg
Country of Origin: United States of America

 

Categories: , SKU: 3500/33-01-00

Description

Overview


Essential details:3500/33-01-00 16-Channel Relay Module BENTLY NEVADA

Products Description

Features

  • 6 channels of temp monitoring
  • Accepts RTD and TC inputs
  • User-programmable alarm setpoints
  • 3500 Rack Configuration Software
  • Greater than 10 MΩ for each lead input
  • Power consumption: 9 watts
  • Operating temp: -22 to 150°F (-30 to 65°C)

The Bently Nevada 3500/61 Temperature Monitor provides six channels of temperature monitoring and accept both Resistance Temperature Detector (RTD) and Thermocouple (TC) temperature inputs. The modules condition these inputs and compare them against user-programmable alarm setpoints. The 3500/61 provide identical functionality except that the 3500/61 provides recorder outputs for each of its six channels.

The user programs the modules to perform either RTD or TC temperature measurements using the 3500 Rack Configuration Software. Different I/O modules are available in RTD/TC non-isolated or TC isolated versions. The user can configure the RTD/TC non-isolated version to accept either TC or RTD, or a mixture of TC and RTD inputs. The TC isolated version provides 250 Vdc of channel-to-channel isolation to protect against external interference.

When used in a Triple Modular Redundant (TMR) configuration, temperature monitors must be installed adjacent to each other in groups of three. When used in this configuration, the system employs two types of voting to ensure accurate operation and to avoid single-point failures.

3500/33-01-00

Analog signal, there are two, voltage or current signal, is generally the signal transmitted by the transmitter, such as the pressure transmitter to detect the water pipe pressure, it will output an analog signal 4- 20ma or 0-10V signal to PLC, PLC for data processing.

Switching quantity input point (DI), processing switching quantity input signal.

Analog input point (AI), processing analog input signal (0-20 MADc,0-5VDC).

Resistance signal (including thermal resistance) input point, processing thermal resistance or general resistance signal.

High speed pulse input point, processing high speed pulse signal.

Voltage (including thermocouple) input point, processing voltage input or thermocouple signal.

There is also communication, used to exchange data with the upper computer or control the subordinate controller instrument driver

1.2 Difference between digital and analog input modules
According to the difference of field input signal, input module can be divided into switching input module and analog input module.

The function of switching input module is to convert various switching signals into TTL standard signals required by CPU. According to the input power supply type, it can also be DC input module and AC input module. The input signal is converted into TTL (5V) standard signal by photoelectric coupling after voltage division, current limiting and filtering.

sunny  He

[Email] sales@xiongbagk.cn

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@xiongbagk.cn

Why Choose Us 3500/33-01-00 16-Channel Relay Module BENTLY NEVADA

We are a professional service provider in the field of industrial automation components. We mainly provide PLC module, DCS card, ESD system card, vibration monitoring system card, turbine control system module, gas generator components, we have established a close cooperative relationship with many PLC and DCS product maintenance service providers. The company has established an e-commerce operation model, which reduces the intermediate links for consumers and provides consumers with high-quality products and satisfactory services. The company has a complete logistics supply system. We can buy directly from abroad and supply equipment and spare parts from different countries and manufacturers to solve your problem.

Packing & Shipping

Package Type: New and original factory separately sealed inner box

Delivery time: Prepare delivery inventory;

The goods will be packed according to the international standard.

1. We will deliver the goods within 3 working days after payment.

2. The new and original factory seal the inner box separately

3. We can send it to you by DHL/TNT/UPS/EMS/ fedex.

Please contact us directly and we will deliver the goods according to your requirements. Best quality assurance

4. We promise that all goods we supply are 100% new and original

5. One year warranty (after delivery date).

Payment method: We accept telegraphic transfer

Shipping

Superiority products 3500/33-01-00 16-Channel Relay Module BENTLY NEVADA

Relay module 3500 / 32-01-00 Temperature monitor 3500/61 (163179-02)
Keypad module 3500 / 33-01-00 Temperature monitor 3500/61 (163179-03)
4-channel Displacement Monitor Module 3500/40 (140734-01, 135489-04) Temperature monitor 3500 / 61-01-00 (163179-02)
Vibration module 3500 / 42-01-00 Instrument frame 3500 / 05-01-01-00-00-00
Vibration module 3500 / 42-04-00 Instrument frame 3500 / 05-01-02-00-00-00
Vibration module 3500 / 42-09-00 Instrument frame 3500 / 05-01-02-00-01
Differential / Axial Position Module 3500 / 45-01 Instrument frame 3500 / 05-02-04-00-00-00
Differential / Axial Position Module 3500 / 45-01-00 Monitoring module 3300 / 50-01-01-00-00
Speed module 3500 / 50-01-00 Monitoring module 3300 / 50-02-01-00-00
Bentley 3500 Monitoring Module Monitoring module 3300 / 52-02-00-00