Essential details:3500/04-01-R0 136719-01 3500/04 Internal Barriers Earthing Module
- Manufacturer : Bently Nevada
- Product No. : 3500/04-01-00
- Product type : 3500/04 Internal Barriers Earthing Module
- Made in U.S.A
- Can add on Certificate Of Origin (COO)
- Internal Barrier Earthing Module (includes front panel).
- Dimensions (Height x Width x Depth) : 24.1 cm x 2.44 cm x 10.31 cm (9.50 in. x 0.96 in. x 4.06 in.)
- Weight : 0.201 kg (0.443 lb.)
- Shipping weight : 1.5 Kg
lf you need to inquire or purchase ,please send the product models to my email or call medirectly .
sunny He
[Email] sales@xiongbagk.cn
[Mobile] 86-18059884797
[WhatsApp] 86-18059884797
[Skype] sales@saulcontrol.com
3500/04-01-R0 136719-01 3500/04 Internal Barriers Earthing Module
provides the lS earth connection through the 3500system backplane.
The lS Earth Module requires a dedicated l/0module position and precludes the use of thismonitorposition forother 3500 System modulesThis limits a standard 19-inch rack to 13 monitorpositions.Furthermore,a numberofinstallationoptions are not available when internal barriersare installed in a 3500 rack.
New Rack installations
The same rack can contain both internal barrierand standard l/0 module types withoutcompromising the separation between hazardousand safe area field wiring.
The ExternalTermination option is not availableforl/O modules with internal barriers becausehazardous area approvals do not allow the use ofintrinsically safe wiring within a multi-cored cableassembly.
Monitors that contain TMR rack options cannotuse internal barrierl/O modules since connectinga transducer to multiple l/O module inputs willcompromise the integrity of the lS system.
A rack that contains any internal barrier modulemust have a 3500/04-011S Earthing Module toprovide the Barrier Module lS earth connection.
The lS Earth Module requires a dedicated l/0module position and precludes the use of thismonitorposition forother 3500 System modulesThis limits a standard 19-inch rack to 13 monitorpositions.Furthermore,a numberofinstallationoptions are not available when internal barriersare installed in a 3500 rack.
New Rack installations
The same rack can contain both internal barrierand standard l/0 module types withoutcompromising the separation between hazardousand safe area field wiring.
The ExternalTermination option is not availableforl/O modules with internal barriers becausehazardous area approvals do not allow the use ofintrinsically safe wiring within a multi-cored cableassembly.
Monitors that contain TMR rack options cannotuse internal barrierl/O modules since connectinga transducer to multiple l/O module inputs willcompromise the integrity of the lS system.
A rack that contains any internal barrier modulemust have a 3500/04-011S Earthing Module toprovide the Barrier Module lS earth connection.