Description
Technical Specifications
| Parameter Name | Parameter Value |
| Product Model / Catalogue Number | HONEYWELL 2MLR-AC22 |
| Manufacturer | Honeywell |
| Product Type | Motor Protector / Manual Motor Starter or Contactor Accessory |
| Rated Operational Current (Ie) | 22 A (as indicated by ‘AC22’) |
| Rated Operational Voltage (Ue) | Up to 690 V AC (typical for industrial motor starters) |
| Utilization Category | AC-3 (Squirrel cage motor: starting, switching off) / AC-1 (Non-inductive loads) |
| Thermal Overload Protection | Adjustable trip setting, typically covering the 22A range. |
| Short-Circuit Protection | May require coordination with an external fuse or circuit breaker (depending on design). |
| Control / Coil Voltage | Multiple standard voltages available (e.g., 24V AC/DC, 110V AC, 230V AC). |
| Number of Poles | 3-pole (for 3-phase motor control) is standard. |
| Mounting | Designed for DIN-rail mounting (35mm). |
| Protection Rating (Enclosure) | IP20 (for installation inside a control cabinet). |
Key Features and Advantages
The HONEYWELL 2MLR-AC22 is a robust and reliable motor management device, likely part of Honeywell’s manual motor starter or contactor-relay series. It is engineered to provide safe and efficient switching, protection, and isolation for three-phase AC motors and other industrial loads up to 22A, ensuring the longevity of electrical equipment and operational safety.
Integrated Motor Protection: A key feature of this unit is its integrated thermal overload protection. It continuously monitors the motor current and will trip to disconnect the power in the event of an overload condition, such as a jammed pump or a failing bearing, thereby preventing costly motor burnout and potential fire hazards. The adjustable trip setting allows for precise matching to the motor’s full-load current. Compact and Versatile Design: Designed for DIN-rail mounting, the 2MLR-AC22 saves valuable panel space. Its modular and versatile design makes it suitable for a wide range of applications, from simple manual on/off control to integration into automated control systems when used as a contactor accessory. The clear ON/OFF indication and manual operator ensure safe and straightforward local control. Durability and Safety: Built to Honeywell’s high-quality standards, this starter is designed for long electrical and mechanical life, capable of withstanding frequent switching operations. It incorporates safety features like a direct opening mechanism, ensuring positive contact separation for safe isolation. This reliability is critical for minimizing unplanned downtime in industrial processes. For assistance selecting the correct coil voltage or integrating this starter into your control scheme, contact our engineers on WhatsApp.
Product Application Scenario
In a small industrial workshop, the HONEYWELL 2MLR-AC22 is used to control a 5.5 kW, 3-phase coolant pump for a CNC machine. Mounted in the machine’s main control cabinet, it provides a local, safe means to manually start and stop the pump. The integrated thermal overload relay is set to the pump motor’s rated current (e.g., 11A). If the pump intake gets blocked, causing the motor to draw excessive current, the thermal element in the 2MLR-AC22 will heat up and trip the mechanism after a time delay, cutting power to the pump and preventing damage. The manual reset button must then be pressed once the fault is cleared, ensuring safe restart. This simple, all-in-one solution provides motor protection, control, and isolation without the need for separate components.
About SaulControl and Our Value Proposition
At SaulControl, I, Zona, along with our technical team, are focused on providing reliable components that form the backbone of industrial control systems. We understand that a device like the HONEYWELL 2MLR-AC22 is a fundamental building block for motor safety and control. We offer more than just the product; we provide application expertise to ensure you select the right device for your specific motor and load characteristics. Our goal is to be your trusted partner, ensuring you have access to quality components and the support needed for successful implementation and long-term reliability.
Product Functionality and Warranty
The primary function of the HONEYWELL 2MLR-AC22 is to provide a safe means of connecting and disconnecting a motor from the power supply, while simultaneously protecting it from damage due to prolonged overloads. It combines the functions of a switch, an isolator, and a thermal overload relay in one compact unit. We guarantee that every unit supplied is genuine Honeywell product, sourced from reliable channels. All products come with a comprehensive 1-year warranty, and our technical support is available to assist with selection and application questions.
Application Areas
The HONEYWELL 2MLR-AC22 is a versatile solution for protecting and controlling small to medium-sized three-phase motors across numerous industries. In General Manufacturing, it is used for machine tools, conveyor belts, fans, and small compressors. Building Automation applications include control of HVAC fans, pumps, and air handling units. The Water and Wastewater sector utilizes it for small chemical dosing pumps and aerators. It is also found in Agriculture for irrigation pumps and in Commercial Facilities for various motor-driven equipment. Any application requiring reliable, standalone protection and control for a motor up to approximately 11 kW (at 400V) is a suitable candidate for this compact motor starter.
Related Products
The 2MLR-AC22 is part of a system for motor control. Related products and accessories include:
- Honeywell Contactors: Higher-capacity or electrically held contactors (like the 2MLR series contactors) for remote/automated control when used in conjunction with a separate thermal overload relay.
- Auxiliary Contact Blocks: Add-on contact blocks (NO/NC) to provide signaling contacts for control circuits or PLC inputs to indicate the starter’s status.
- DIN-Rail Mounted Circuit Breakers or Fuses: Upstream devices required to provide short-circuit protection for the motor branch circuit, as the manual motor starter typically provides overload protection only.
- Motor Protection Circuit Breakers (MPCBs): Alternative devices that combine short-circuit and overload protection in one unit, such as other Honeywell or third-party brands.
- Control Transformers: To provide the appropriate control voltage (e.g., 24V AC) for the coil if the starter is used in a contactor configuration.
- Push Buttons and Selector Switches: For creating local control stations to operate the starter remotely.
- Horsepower Rated Motor Disconnects: Alternative manual disconnecting switches for motor circuits.
For detailed datasheets, motor sizing assistance, or a commercial quotation for the HONEYWELL 2MLR-AC22, please contact our team:
• WhatsApp: Contact on WhatsApp
• Email: sales@saulcontrol.com
• Phone: +86 18150899970
We supply genuine industrial components, provide expert application support, and offer a full 1-year warranty. Looking for a different current rating or a specific accessory? Contact us—we can help find the right solution for your motor control needs.
1 Year Warranty